A 2-user electronic safe lock from SECURAM Systems (Model EM-1701A EntryPad with DL-1701 D-Drive Deadbolt Lock Body). Motor-driven locking with automatic re-lock, a no-twist cable design for long-term durability, and a deadbolt drilled and tapped for bolt extensions or custom attachments.
Category: Safe Locks
Key Features
Motor-Driven Locking
Motor-driven locking action with automatic re-lock after 6 seconds.
No-Twist Cable Design
A no-twist cable design for long-term durability.
D-Drive Deadbolt
The D-Drive Deadbolt is drilled and tapped for bolt extensions or custom attachments.
Long Battery Life
Powered by a single 9V battery, delivering over 10,000 openings per battery.
SureLock Non-Volatile Memory
Codes are never lost during battery replacement. For indoor use.
Basic Operation — Opening the Lock
Manufacturer default codes (must be changed immediately):
Manager Code: 1-1-1-1-1-1 · User Code: 1-2-3-4-5-6
ⓘ If the entry is invalid, repeated beeps will sound and the lock will not open. Standby: to conserve battery, the system reverts to standby after 10 seconds of no key press (two short beeps). Wake the keypad by pressing any key.
Manager Programming
⚠️ Always perform all programming with the lock unlocked and the safe door open. The system will not accept a code set to six zeros. Verify any new code at least 3 times before closing the door.
Change the Manager Code:
1. Enter 0-0-0-0-0-0 (six zeros) — one beep
| Action | Steps (after entering program mode) |
|---|---|
| Add | Press “1”, enter a 6-digit code, re-enter to confirm — one beep confirms success |
| Enable | Press “1” — one beep confirms the User Code is enabled |
| Disable | Press “2” — one beep confirms the User Code is disabled |
| Delete | Press “3” — one beep confirms the User Code is deleted |
User code – Add/Enable/Disable/delete
Wrong Entry Penalty
- 4 consecutive invalid codes triggers a 5-minute lockout
- During lockout, the unit beeps at 5-second intervals
- Pressing keys during lockout does not restart or lengthen the penalty — it will not respond
- Removing the battery interrupts the countdown, but it resumes when the battery is reinstalled until the full 5 minutes have elapsed
Power & Battery
- Battery: 1 × 9V standard Alkaline (Duracell or Energizer recommended)
- Recommended replacement: annually
- Low Battery Alert: 8 repeated beeps during an unlock operation — replace immediately
- SureLock non-volatile memory: codes are retained during battery replacement
Specifications
| Power Supply | DC 9V (operating range DC 6V–11V) |
| Working Temperature | 0°C to +49°C |
| Working Humidity | <90% |
| Password Length | 6 digits |
| Mechanical Life Span | >10,000 cycles (UL) / >100,000 (SECURAM) |
| Environment | For indoor use only |